De grootste kennisbank van het HBO

Inspiratie op jouw vakgebied

Vrij toegankelijk

Terug naar zoekresultatenDeel deze publicatie

Critical Strain Determination Based on the Euler-Fresnel Jig

Rechten: Alle rechten voorbehouden

Critical Strain Determination Based on the Euler-Fresnel Jig

Rechten: Alle rechten voorbehouden

Samenvatting

When considering a composite strip or plate under certain thermal and environmental conditions
and loadings, there is a minimum strain threshold for the appearance of the first micro crack. The
associated strain level is defined here as “critical strain”.
There are various active displacement methods to measure this strain level (by tension and
bending). The registration of the first micro crack is however challenging. Therefore, some alternative
methods have been developed like the Bergen ellipse [1]. With this method, a relatively thin strip is
forced by clamping to “follow” the elliptical contour of the jig. The strip undergoes various strain
levels from 0% to 2% or 3%. However, the strain distribution as a function of the strip length is far
from linear. This causes inaccurate readings and high error sensitivity for certain areas on the ellipse.
To overcome this problem, a novel jig design is introduced here; this design is based on a perfectly
linear strain distribution along the strip’s length. The resulting curve is a classical one known as the
Euler-Fresnel curve [2]. The linearity and the constant, low sensitivity to measurement errors
guarantees high accuracy. Only at the beginning and the end of the strip, the measured strain might
deviate from the real one, especially when the thickness of the strip is moderately less (Dh > 0.1 [mm])
than the height of the slot, Figure 9. The jig is a low cost device that can easily be placed in climate
cabinets for e.g. cryo-cycling.
In this paper we focus on the mathematical derivation of the jig, compare it to the Bergen ellipse,
and provide the full consideration of the associated primary and secondary forces and moments. In
addition, a comprehensive strength analysis of various lay-ups is provided for the maximum strain
level of 2%. The paper ends with some key conclusions and recommendations.

Toon meer
Trefwoorden
OrganisatieHogeschool Inholland
AfdelingDomein Techniek, Ontwerpen en Informatica
LectoraatGroot Composiet
Gepubliceerd in20th International Conference on Composite Materials Kopenhagen
Datum2015-08-19
TypeBijdrage aan periodiek